PAPERS
Dai Qiang, Yu Qi, Rao Qing, Zhou Wei and Yang Mohua
Abstract: Based on probability and statistical theory,pulse and step acceleration signal response models of capacitive micro-accelerometer with single-sided driving mode and double-sided driving mode are investigated,respectively,which are established on the assumption that the comb gaps conform to the uniform distribution within a given scope induced by the MEMS processing non-ideality.The precision of the models has been verified by the FEA and monte carlo methods with ANSYS software.The deviation between them is less than 10%.The models suggest that the reliable operation ranges of the accelerometers will decrease 10%~15% when the comb gaps deviate 0~20% from the ideal value.The models can be used in the estimation of the reliable operation ranges of capacitive accelerometers.
Key words: micro-accelerometers, comb gap, pulse and step signal response models, reliable operation range
Article views: 2684 Times PDF downloads: 1363 Times Cited by: 0 Times
Received: 18 August 2015 Revised: 23 January 2008 Online: Published: 01 July 2008
| Citation: |
Dai Qiang, Yu Qi, Rao Qing, Zhou Wei, Yang Mohua. Pulse and Step Signal Response Models of Micro-Accelerometers Based on the Comb Gaps Deviation[J]. Journal of Semiconductors, 2008, 29(7): 1391-1395.
****
Dai Q, Yu Q, Rao Q, Zhou W, Yang M H. Pulse and Step Signal Response Models of Micro-Accelerometers Based on the Comb Gaps Deviation[J]. J. Semicond., 2008, 29(7): 1391.
|